Graham - Engineering Answers

  |  home | vacuum products | heat transfer products | surface condensers | service | technical library | contact us |


      Product overview 

      Advantages 

      Applications 

      Photo gallery 

      Technical library 

      Inquiry information 


 Heliflow® heat exchangers 
 Clean steam generators 
 MicroMix®II water heaters 
 Plate exchangers 
 Desuperheaters 

Desuperheater Advantages

Turndown ratio     Compact designs     Outlet superheat     Materials
Pressure drop     Design codes     Water conditions     Orientation


Design codes



Graham desuperheaters are designed and fabricated to pressure vessel code ASME Section VIII, Div. 1. If the desuperheater will be located within two pressure control valves from a boiler, ASME Section I applies. ASME stamp for either design code is available for a price adder. Alternatively, we can design and fabricate to piping code ANSI B31.3 or B31.1 (within two pressure control valves from a boiler).

Graham desuperheaters can be built to comply with either ASME Section VIII, Div. 1 (a pressure vessel specification) or ANSI B31.3 (a piping specification). Likewise, we can build desuperheaters in compliance with either ASME Section I or ANSI B31.1.



<  top  >
Graham Corporation, 20 Florence Ave., Batavia, NY 14020 USA - phone: 585.343.2216 fax: 585.343.1097
email: equipment@graham-mfg.com